RAID Explained
In the IT world,
hardware failure is not about if it will happen, but when it will
happen. If you run a server that has any sort of important data on it,
protection of that data is very important. Many people chose to
implement a redundant RAID (redundant array of independent disks)
array to help deal with the risk of having a hardware failure. There
are several types of RAID that are appropriate for servers, and there
are several ways they can be effectively implemented.
IBM patented the idea of
RAID in 1978. It was not until 1988 that the RAID levels that we have
come to know were defined. This development was done at University of
California in Berkeley. Now days RAID is used in many servers
throughout the world and even in desktop machines.
RAID 1
The use of a mirroring RAID array, or RAID 1 is useful in server
situations. It creates an exact copy of the original drive. If either
of the drives fail, the system can continue operations without any
downtime. Then the new hard drive can be put into the system and it
can rebuild the array.
This system is considered a little less desirable than a RAID 5 setup
for most situations of day-to-day operation. However, it has several
applications where the use of RAID 1 can be beneficial. One advantage
is that it has a faster seek time than RAID 5, which makes it
beneficial for data that, will not be written to often. The main
advantage is that some 1U servers do not have room for a 3 drive
array, so implementing RAID 1 is often considered better for
reliability than no RAID at all. However, the most useful way that I
have seen RAID 1 used in the real world is as backups. With a
hot-swappable setup, the mirror disk can be removed and kept as backup
much the same way as a tape backup can be stored. This proves to be
very useful for mission critical systems since it allows for a system
to be brought back online after a data failure, or the system to be
brought up on separate hardware after a catastrophic hardware failure.
RAID 5
Probably the most common disk array used in enterprise computing is a
RAID 5 array. This is because it maximizes disk usage, reliability,
and speed of access. To get an idea of how it works, there are usually
3 drives in an array that each have their data divided between two
other drives.
On mission critical servers, RAID 5 is often used with a cache that
has an attached battery backup. This ensures that in a power failure,
no transactions are lost from the server. Often times database servers
with high amounts of transactions will have a battery unit since the
RAID card would cache transactions before waiting, a power failure
could result in an inconsistent database or critical data loss.
RAID 10
This type of RAID array requires 4 or more drives. At the top level is
a RAID 0 array which combines lower level RAID 1 arrays. This type of
RAID array has a benefit over RAID 5 in that it has faster write
times. This often makes it a little bit better of a choice than RAID 5
for database servers.
Space Calculations
To calculate RAID 1 you simply divide the total drive space by 2. For
RAID 5 you multiply the total space of the drives by the number of
drives over 1 to get total usable space. Then for RAID 10 you add up
each RAID 1 array.
RAID1
2 80 GB Drives
80/2=80
RAID5
3 80 GB Drives
240*(2/3)=160
5 80 GB Drives
400*(4/5)=320
RAID10
4 80GB Drives
2 RAID 1 Arrays = 160GB usable
Hardware RAID
The use of hardware RAID
arrays no longer makes as much sense as it once did. There are still
reasons to use a hardware RAID over a software RAID. The first reason
to use hardware RAID is that it usually has a cache, which speeds up
the operation of the array dramatically. The second advantage is that
it will not cut into system resources as much as software RAID. The
biggest advantage is in the possibility of having a battery backed up
cache. This will help prevent corruption from an unexpected power
issue or a system crash.
Software RAID
Although historically all RAID arrays were completely hardware based,
there is a growing popularity of software RAID. One of the reasons for
this is that CPU speeds are now fast enough that the processing time
involved managing the RAID array is really minimal compared to the
overall processor.
One of the major advantages of software RAID is that it can be setup
on commodity hardware so the physical disks can easily be moved to
another server in the event of a hardware failure that does not
involve the disks. The biggest disadvantage is that software raid has
no cache so the limit to the speed data can flow from the Operating
System is the limit of the drives.
Notifications
Lets assume you have a working RAID setup now. Now if a drive fails
the system continues like nothing ever happened. The problem is,
without notification of a drive failure, there is no reason to have
raid. So make sure you setup a system to notify you whenever a drive
fails. It may notify you by email, page you, or on some control panel.
The important thing is that you know before two drives fail and render
the array useless.
Conclusion
Hopefully you will be able to make some important purchasing decisions
for you next server after reading this article. There are a lot of
things to consider when planning data availability so make sure you
spend enough time to get everything right. Remember that no single
RAID setup is best for all applications.
by
Tyler Weaver
|
|
|